Photo 1 of 6
Rubber & plastics testing
Compression stress relaxometer jigs
Shawbury- stress relaxation jig: used for the discontinuous method, this fixture works on the principle of electrical contact between the load cell and the head of the jig. The contact is broken only when the force applied by the relaxometer marginally exceeds the counterforce exerted by the test sample.
Wykeham Farrance stress relaxation jig: used for the discontinuous method, this fixture works by applying a slight increase in the compression of the test specimen.
Wykeham Farrance stress relaxation jig: the fixed-height jig (WAC11-190) is supplied with a pair of fixed spacers. The spacers are sized to give 25% compression of a standard 6.3 mm thick sample. Bespoke spacers can be made for specific applications.
Fixed-height jigs are generally used when the same test is repeated often (e.g. the same sample thickness and compression ratio), whereas adjustable jigs are used where the sample size or compression ratio varies.
The jigs compress the sample by a known percentage and maintain that compression throughout the test. With the jig fitted to the WAC11, the counterforce can easily be measured at the prescribed time intervals. The jigs can then be stored under the required conditions until the next test time without compromising the known compression percentage. jig assemblies are made of stainless steel as standard but can be manufactured in other materials for specific applications.
Application:
- Wykeham Farrance stress relaxation jig: provides a known compression percentage when measuring the compression stress relaxation (CSR) characteristics of elastomers and rubber products (e.g. seals, O-rings) as required by the relevant standards.
- The fixed-height jig (C11/1) is supplied with one fixed spacer, whose height is determined by the sample size and the required percentage compression. A number of standard fixed-height spacers are available to suit different sample heights and percentage compressions.
- Refer to the specifications for the range of C11/1 fixed-height jigs. Bespoke spacers can be made for specific applications.
- The adjustable-height jig (C11/6) is supplied with one adjustable spacer, so the required compression ratio can be achieved on samples of varying heights. The distance between the upper and lower platen faces can be adjusted from 0.0 mm to 12.0 mm.
Supplied with the Wykeham Farrance stress relaxation jig:
- Wykeham Farrance jig
- Spacer for 25% compression of a 6.3 mm sample (qty 2)
- Calibration certificate
Supplied with the Shawbury- stress relaxation jig:
- Shawbury- jig
- Spacer (type depends on the jig version)
Calibration:
- Manufacturer's calibration certificate included as standard
Specifications
- Brand
- Wallace Instruments · WAC11/1 +4
- Standards
- BS ISO 3384-1 Method B, BS ISO 3384-2 Method B, ASTM D6147 Method B
- Operating temperature
- −40 °C to +250 °C
On request
Variants & pricing
Option set 1
- Description
- Push Rod to fit WAC11 instrument
WAC11-193On request- Description
- WAC11-190 fixture locator for WAC11 instrument
WAC11-194On request- Description
- Sample locating tool - set of three
WAC11-195SOn request
Option set 2
- Dimensions (mm)
- 120 (h) x 100 (Ø)
- Weight
- 1.8kg
WAC11/1On request- Dimensions (mm)
- 35 (h) x 44.5 (Ø)
- Weight
- 1.2 kg
WAC11-190On request