Skip to main content
Saint-Tech

Titration

Coulometric Karl Fischer titrator, T931

Coulometric Karl Fischer titrator for accurate determination of the water content of solids and liquids, with reliable results and a wide measuring range (0.001–100%). The 10-inch TFT touchscreen makes it easy to operate, and multiple safety features keep the operator out of contact with toxic reagents. Used in the petroleum, chemical, food, cosmetics and pharmaceutical industries and in other fields.

  • 10-inch TFT touchscreen with Android: user-friendly interface; parameters are set and changed with a tap, and data is browsed by swiping left and right, for more efficient work
  • Modular menu for quick, accurate access to every sub-screen and smooth navigation
  • During a test the instrument shows the titration curve, parameters and results in real time, so the whole titration can be monitored as it runs
  • Multiple result units: mg%, ppm, H₂O, mL, mg/mL, mg/g, etc.; data retrieval function for quick access to historical records
  • V-T and E-T curves can be switched at any time during analysis and zoomed in or out manually; 8 GB of storage for methods, data, traceability documents and more
  • Sealed, secure reagent management: the reagent is changed automatically without opening the titration cell, keeping atmospheric moisture out; after a reagent change the equilibration time is short, and operator contact with the toxic reagent is reduced
  • Injection ports in several sizes for different sample introduction methods
  • Waste overflow protection prevents the waste bottle from overflowing when full
  • Magnetic stirrer included as standard, with manual and automatic stirring, for more efficient titration
  • Plug-in anti-fall reagent bottle rack, freely configurable, for 250 mL, 500 mL and 1000 mL reagent bottles
  • Built-in methods with one-touch start: preset methods such as titre, blank value and water content determination start with a single touch, without starting the water content measurement manually
  • The instrument detects when a sample has been added and starts the measurement automatically; analysis parameters can also be customised to suit specific samples
  • Multiple electrolysis currents: the electrolysis current switches automatically according to the water content of the sample
  • Four end-point criteria — relative drift stop, absolute drift stop, delayed end point and maximum time stop — for precise, reliable testing even of complex or difficult samples
  • Complies with FDA 21 CFR Part 11
  • Audit trail: every operation carried out on the instrument is logged in the background
  • Four-level permission management; the permissions of each level can be customised
  • Electronic signature and tamper-proof data output for secure, verifiable data integrity
  • Password security: passwords can be given an expiry date after which a change is enforced before the instrument can be used again; password complexity and ageing period are configurable
  • Screen saver: the screen locks after a set time, while the instrument keeps working in the background
  • Wi-Fi, USB, RS232 and BNC interfaces, among others: remote printing on a Wi-Fi printer or printing via RS232, and operation with a mouse and keyboard

Specifications

Brand
Hanon · T931
Measuring method
Coulometric
Water content measuring range
0.001–100%
Recommended measuring range
10 µg – 200 mg H₂O
Polarisation current range
1–24 µA
Polarisation current resolution
0.01 µA
Polarisation current error
0.05 µA
Voltage range
0–1999 mV
Voltage resolution
0.1 mV
Voltage error
±0.2 mV
Electrolysis current
10, 20, 50, 100, 200 and 400 mA
Maximum electrolysis rate
37.34 µg H₂O/s (2240 µg H₂O/min)
Electrolysis accuracy
≤0.2%
Electrolysis resolution
0.1 µg H₂O
Number of methods
150
Export format
Excel, PDF
Display
10-inch TFT capacitive touchscreen
Curve display
E-T
Drift correction
Manual, automatic or off
FDA 21 CFR Part 11 compliance
Yes
Audit trail
Yes
Permission management
Four levels (super administrator, supervisor, operator, IT)
Number of users
30
Storage
8 GB
Titration cell
200 mL
Communication interfaces
Wi-Fi, USB, Ethernet, RS232, BNC
Stirring
Magnetic stirring
Compatible printers
Wireless laser printer, wired micro printer
Power supply
220 V ±10%, 50–60 Hz

On request

All options (1)

Variants & pricing

  • Coulometric Karl Fischer titrator, T931

    T931On request

Related products