Photo 1 of 2
Flow measurement
Intrinsically safe area velocity flow meter, 2150EX
Area velocity flow meter approved by Baseefa (ATEX) and CSA (Class I, Division 1) for potentially explosive atmospheres such as manholes, digesters and storage tanks.
- All-digital smart probe, factory-calibrated for temperature and a 3 m span
- Rugged, submersible IP68 (NEMA 4X, 6P) enclosure
- Software updates without removing the meter from the hazardous area
- RS232EX isolator cable for safe laptop connection in the field
- Measures velocity in flows down to 25 mm deep
- Applications: open-channel flow in hazardous locations, inflow and infiltration and sewer overflow studies
Specifications
- Brand
- Teledyne ISCO · 68-2000-043 +1
- Module size (H × W × D)
- 22.6 × 28.0 × 19.3 cm including battery compartment
- Module weight
- 3.0 kg without batteries
- Enclosure
- IP68 (NEMA 4X, 6P, self-certified)
- Power required
- 7.0 to 9.0 V DC, 100 mA typical, 1 mA standby
- Operating temperature
- −40 to 60 °C
- Level-to-area conversions
- Round, U-shaped, rectangular, trapezoidal, elliptical channels with silt correction; up to 50 level-area points
- Weirs
- V-notch, rectangular, Cipolletti, Isco Flow Metering Inserts, Thel-Mar
- Flumes
- Parshall, Palmer-Bowlus, Leopold-Lagco, trapezoidal, H, HS, HL
- Data storage
- 395,000 bytes (up to 79,000 readings)
- Storage interval
- 15 or 30 s; 1, 2, 5, 15 or 30 min; 1, 2, 4, 12 or 24 h
- Velocity measurement
- Doppler ultrasonic, 500 kHz; −1.5 to +6.1 m/s; ±0.03 m/s (−1.5 to 1.5 m/s), ±2% of reading (1.5 to 6.1 m/s)
- Level measurement
- Submerged pressure transducer, 0.010 to 3.05 m, ±0.003 m
- Approval (flow module)
- II 1G EEx ia IIB T4 (−40 °C < Ta < +60 °C)
On request
Variants & pricing
- Version
- With AV sensor, 2196EX battery module and handle
68-2000-043On request- Version
- Module with AV sensor, without battery module
68-2000-021On request