Skip to main content
Saint-Tech

Photo 1 of 5

Air disinfection & purification

NBVE dual-purpose UV-C flow germicidal lamp

NBVE dual-purpose lamps combine a closed UV-C flow chamber, for air disinfection while people are present (function I), with external UV-C tubes for direct irradiation of the whole room when nobody is inside (function II). The two functions are switched on separately or together.

Versions: N — wall-mounted; S — ceiling-mounted; P — on a mobile stand; L — with working time counters; RC — with remote control.

Also listed in: Other products: Cleaning & disinfection

Specifications

Brand
ULTRAVIOL · NBVE 60/30 N +15
Supply voltage
230 V 50 Hz
Useful lifetime of the bulbs
9000 h
Anti-shock protection class
I
Ingress protection code
IP 20

Variants & pricing

  • Mounting
    wall-mounted
    Working time counter
    —
    Power consumption
    115 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 1x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 145 x 285 mm
    Total lamp mass
    8,0 kg
    NBVE 60/30 NOn request
  • Mounting
    ceiling-mounted
    Working time counter
    —
    Power consumption
    115 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 1x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 285 x 215mm
    Total lamp mass
    8,0 kg
    NBVE 60/30 SOn request
  • Mounting
    on mobile stand
    Working time counter
    —
    Power consumption
    115 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 1x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    285 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,0 kg
    NBVE 60/30 POn request
  • Mounting
    wall-mounted
    Working time counter
    —
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 1x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 145 x 285 mm
    Total lamp mass
    8,0 kg
    NBVE 110/55 NOn request
  • Mounting
    ceiling-mounted
    Working time counter
    —
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 1x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 285 x 215mm
    Total lamp mass
    8,0 kg
    NBVE 110/55 SOn request
  • Mounting
    on mobile stand
    Working time counter
    —
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 1x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    285 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,0 kg
    NBVE 110/55 POn request
  • Mounting
    on mobile stand
    Working time counter
    —
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 2x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    355 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,5 kg
    NBVE 60/60 P RCOn request
  • Mounting
    on mobile stand
    Working time counter
    —
    Power consumption
    185 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 2x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    355 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,5 kg
    NBVE 110/110 P RCOn request
  • Mounting
    wall-mounted
    Working time counter
    two working time counters
    Power consumption
    115 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 1x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 145 x 285 mm
    Total lamp mass
    8,0 kg
    NBVE 60/30 NLOn request
  • Mounting
    ceiling-mounted
    Working time counter
    two working time counters
    Power consumption
    115 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 1x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 285 x 215mm
    Total lamp mass
    8,0 kg
    NBVE 60/30 SLOn request
  • Mounting
    on mobile stand
    Working time counter
    two working time counters
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 2x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    285 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,0 kg
    NBVE 60/30 PLOn request
  • Mounting
    wall-mounted
    Working time counter
    two working time counters
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 1x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 145 x 285 mm
    Total lamp mass
    8,0 kg
    NBVE 110/55 NLOn request
  • Mounting
    ceiling-mounted
    Working time counter
    two working time counters
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 1x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    1125 x 130 x 285 mm
    Overall dimensions
    1190 x 285 x 215mm
    Total lamp mass
    8,0 kg
    NBVE 110/55 SLOn request
  • Mounting
    on mobile stand
    Working time counter
    two working time counters
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 1x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    285 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,0 kg
    NBVE 110/55 PLOn request
  • Mounting
    on mobile stand
    Working time counter
    two working time counters
    Power consumption
    145 W
    Source of UV-C radiation
    flow function 2x30 W direct radiation function (external UV-C tube): 2x30 W
    UV-C radiation intensity at the distance of 1 m
    100 µW / cm²
    Fan capacity
    132 m³ / h
    Cubage of disinfected room
    25-50 m³
    Effective area of the lamp
    10-20 m²
    Lamp body dimensions
    355 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,5 kg
    NBVE 60/60 PL RCOn request
  • Mounting
    on mobile stand
    Working time counter
    two working time counters
    Power consumption
    185 W
    Source of UV-C radiation
    flow function 2x55 W direct radiation function (external UV-C tube): 2x55 W
    UV-C radiation intensity at the distance of 1 m
    150 µW / cm²
    Fan capacity
    199 m³ / h
    Cubage of disinfected room
    45-90 m³
    Effective area of the lamp
    18-36 m²
    Lamp body dimensions
    355 x 130 x 1125 mm
    Overall dimensions
    600 x 600 x 1300 mm
    Total lamp mass
    12,5 kg
    NBVE 110/110 PL RCOn request

Related products