Composition & component analysis

Organic elemental analyser, E500

  • Standby and wake-up: after analysis the instrument can cool down automatically and switch to sleep/standby mode, and it can be scheduled to wake up automatically. This avoids repeated waiting for heating and cooling at start-up and shutdown; standby also saves carrier gas and reduces power consumption
  • Audit trail: the software complies with FDA 21 CFR Part 11. Three levels of user permissions, with no limit on the number of users. All instrument operations and setting changes are recorded and traceable, keeping experimental data authentic and secure
  • Wireless transfer of balance weighing data: an industrial-grade wireless module collects the weighing results from the balance automatically, reducing workload and avoiding errors
  • Delayed air cooling: after shutdown following analysis, the cooling fan keeps running until the furnace has cooled to a safe temperature and then switches off automatically, saving cooling time and extending the instrument's service life
  • Calibration curve method: linear or non-linear calibration; the order of the calibration curve can be set by the user

Specifications

Brand
Hanon · E500
Autosampler
120-position sample tray; sample introduction in crucibles; in-situ crucible replacement at high temperature
Gas separation method
Adsorption–desorption separation
High-temperature combustion and reduction
Combustion temperature up to 1400 °C, ensuring complete combustion of the sample
Analysis time
Approx. 3–4 min per element
Sample size
Max. 1.5 g or a sample volume of 1 ml
Detection range
Maximum dynamic range of element content: C 0–30 mg absolute or 0–100%; H 0–4 mg absolute or 0–100%; N 0–10 mg absolute or 0–100%; S 0–5 mg absolute or 0–100%; O 0–3 mg absolute or 0–100%
Repeatability error
Standard deviation <0.1% (10 mg sulfadiazine standard)
Detection limit
C, H, N, S: <30 ppm (TCD detector); O: <20 ppm (IR detector)
Detectors
C/H/N/S mode: thermal conductivity detector (TCD); O mode: non-dispersive infrared detector (NDIR)
Working gases
Carrier gas: helium (He), purity 99.999%; combustion gas: oxygen (O₂), purity 99.999%
Dimensions (L × W × H)
735 × 560 × 1160 mm (including autosampler)
Net weight
100 kg (including autosampler)
Power supply
220 V AC ±10%, 50 Hz
Computer
PC running Windows 7 or later, with a USB or RS232 interface
Operating ambient temperature
15–30 °C
Relative humidity
≤85%

On request

All options (1)

Variants & pricing

  • Organic elemental analyser, E500

    E500On request