Skip to main content
Saint-Tech

Photo 1 of 2

Automatic samplers

Portable refrigerated wastewater sampler, BLZZRD

Portable refrigerated sampler built on the 6712 controller, cooled from AC line power or a 12 V DC battery, for moving from site to site or short-term studies.

  • A 12 V deep-cycle battery delivers 48 hours or more of refrigeration; cooling stays on standby until the first sample is drawn
  • With AC and battery connected, power switches to the battery during an outage
  • Composite (single bottle) or sequential (multi-bottle) sampling
  • Pacing by time, non-uniform time, flow or external event; pause-and-resume; random interval collection
  • SDI-12 interface; NEMA 4X, 6 (IP67) controller enclosure
  • Sample delivery at the EPA-recommended velocity of 2 ft/s, even at 26 ft head height
  • Applications: stormwater runoff compliance, TMDL and watershed monitoring, enforcement monitoring

Bottle configuration, suction line and strainer are ordered separately; 12 V DC operation needs an external battery.

Specifications

Brand
Teledyne ISCO · 68-2964-000
Size (W × D × H)
71 × 47 × 80 cm
Weight (dry, without battery)
34 kg
Power requirements
12 V DC, 6 A (external battery) or 90 to 264 V AC, 47 to 63 Hz, 2 A
Bottle configurations
1 × 19 l poly; 1 × 9.5 l glass; 1 × 9.5 l poly; 4 × 3.7 l poly; 4 × 1.8 l glass; 14 × 950 ml poly
Suction tubing
1 to 30 m, vinyl or PTFE, 1 cm inside diameter
Pump tubing life
Typically 1,000,000 pump counts
Maximum lift
8.5 m
Typical repeatability
±5 ml or ±5% of the average volume in a set
Typical line velocity
0.91 m/s at 0.9 m head; 0.87 m/s at 3.1 m; 0.83 m/s at 4.6 m
Controller dimensions (H × W × D)
26 × 32 × 25 cm
Controller weight
5.9 kg
Operating temperature
0 to 49 °C
Controller enclosure
NEMA 4X, 6 (IP67)
Flow meter signal input
5 to 15 V DC pulse or 25 ms isolated contact closure
External trigger
Starts sample collection and cooling from a contact closure
Composite samples
1 to 999 samples
Programmable sample volumes
10 to 9,990 ml in 1 ml increments
Sample frequency
1 minute to 99 hours 59 minutes in 1-minute increments; non-uniform times; 1 to 9,999 flow pulses
Sampling modes
Uniform time, non-uniform time, flow, event
Sample retries
Up to 3 attempts if no sample is detected
Rinse cycles
Up to 3 automatic rinses of the suction line per sample
Program storage
5 sampling programs
Sampling stop/resume
Up to 24 real-time/date commands
Refrigerant
Fluorinated greenhouse gases with a GWP greater than 150

On request

All options (1)

Variants & pricing

  • 68-2964-000On request