Photo 1 of 2
Automatic samplers
Compact portable water sampler, 6712C
The capabilities of the 6712 sampler in a smaller package with a tapered, narrow 45.7 cm diameter for small or offset manholes, using the same 6712 controller.
- SDI-12 interface for multi-parameter water-quality sondes and other compatible devices
- Standard 512 kB memory for logging environmental data
- Choice of 5 bottle configurations, from 24 × 500 ml to 1 × 2.5 gallon
- Rugged ABS plastic shell; NEMA 4X, 6 (IP67) controller enclosure
- Foam-insulated base holds up to 6.8 kg of ice
- Sample delivery at the EPA-recommended velocity of 2 ft/s, even at 26 ft head height
- Pump revolution counter and patented liquid detection sensor for accurate sample volumes
- Applications: wastewater effluent, stormwater and CSO monitoring, permit and pretreatment compliance
Power source, bottle configuration, suction line and strainer are ordered separately.
Specifications
- Brand
- Teledyne ISCO · 68-6710-071 +1
- Size (H × Ø)
- 70.1 × 45 cm
- Weight (dry, without battery)
- 14 kg
- Bottle configurations
- From 24 × 500 ml PE to 1 × 9.5 l PE or glass
- Power requirements
- 12 V DC (battery or AC power converter)
- Programmable sample volumes
- 10 to 9,999 ml in 1 ml increments
- Suction tubing
- 1 to 30 m, vinyl or Teflon, 1.0 cm inside diameter
- Pump tubing life
- Typically 1,000,000 pump counts
- Maximum lift
- 8.5 m
- Typical repeatability
- ±5 ml or ±5% of the average volume in a set
- Typical line velocity
- 0.91 m/s at 0.9 m head; 0.87 m/s at 3.1 m; 0.83 m/s at 4.6 m
- Liquid presence detector
- Non-wetted, non-conductive sensor; compensates automatically for changes in head height
- Controller dimensions (H × W × D)
- 26.1 × 31.7 × 25.4 cm
- Controller weight (dry)
- 5.9 kg
- Operating temperature
- 0 to 49 °C
- Controller enclosure
- NEMA 4X, 6 (IP67)
- Program memory
- Non-volatile ROM
- Flow meter signal input
- 5 to 15 V DC pulse or 25 ms isolated contact closure
- Composite samples
- Programmable from 1 to 999 samples
- Real-time clock accuracy
- 1 minute per month, typical
- Sample frequency
- 1 minute to 99 hours 59 minutes in 1-minute increments; non-uniform times; 1 to 9,999 flow pulses
- Sampling modes
- Uniform time, non-uniform time, flow, event
- Sample retries
- Up to 3 attempts if no sample is detected
- Rinse cycles
- Up to 3 automatic rinses of the suction line per sample
- Program storage
- 5 sampling programs
- Sampling stop/resume
- Up to 24 real-time/date commands
- Controller diagnostics
- RAM, ROM, pump, display and distributor
On request
Variants & pricing
- Version
- Standard base
68-6710-071On request- Version
- Jumbo Base
68-6710-141On request