Skip to main content
Saint-Tech

Photo 1 of 2

Automatic samplers

Full-size portable water sampler, 6712

Portable sequential or composite sampler with the 6712 controller, a powerful peristaltic pump, versatile programming and optional plug-in modules for integrated flow measurement.

  • SDI-12 interface for multi-parameter water-quality sondes and other compatible devices
  • Standard 512 kB memory for logging environmental data
  • Choice of 11 glass and plastic bottle configurations, from 24 × 1 l to 1 × 21 l
  • Rugged ABS plastic shell; NEMA 4X, 6 (IP67) controller enclosure
  • Foam-insulated base holds up to 13.5 kg of ice to preserve samples
  • Sample delivery at the EPA-recommended velocity of 2 ft/s, even at 26 ft head height
  • Pump revolution counter and patented liquid detection sensor for accurate sample volumes
  • MCERTS certified
  • Applications: wastewater effluent, stormwater and CSO monitoring, permit and pretreatment compliance, PFAS sample collection

Power source, bottle configuration, suction line and strainer are ordered separately.

Specifications

Brand
Teledyne ISCO · 68-6710-070 +1
Size (H × Ø)
68.6 × 50.7 cm
Weight (dry, without battery)
15 kg
Bottle configurations
24 × 1 l PP or 350 ml glass; 24 × 1 l ProPak bags; 12 × 1 l PP or 950 ml glass; 8 × 2 l PE or 1.8 l glass; 4 × 3.8 l PE or glass; 1 × 9.5 l PE or glass; 1 × 21 l PE or 19 l glass (with Jumbo Base)
Power requirements
12 V DC (battery or AC power converter)
Programmable sample volumes
10 to 9,999 ml in 1 ml increments
Suction tubing
1 to 30 m, vinyl or Teflon, 1.0 cm inside diameter
Pump tubing life
Typically 1,000,000 pump counts
Maximum lift
8.5 m
Typical repeatability
±5 ml or ±5% of the average volume in a set
Typical line velocity
0.91 m/s at 0.9 m head; 0.87 m/s at 3.1 m; 0.83 m/s at 4.6 m
Liquid presence detector
Non-wetted, non-conductive sensor; compensates automatically for changes in head height
Controller dimensions (H × W × D)
26.1 × 31.7 × 25.4 cm
Controller weight (dry)
5.9 kg
Operating temperature
0 to 49 °C
Controller enclosure
NEMA 4X, 6 (IP67)
Program memory
Non-volatile ROM
Flow meter signal input
5 to 15 V DC pulse or 25 ms isolated contact closure
Composite samples
Programmable from 1 to 999 samples
Real-time clock accuracy
1 minute per month, typical
Sample frequency
1 minute to 99 hours 59 minutes in 1-minute increments; non-uniform times; 1 to 9,999 flow pulses
Sampling modes
Uniform time, non-uniform time, flow, event
Sample retries
Up to 3 attempts if no sample is detected
Rinse cycles
Up to 3 automatic rinses of the suction line per sample
Program storage
5 sampling programs
Sampling stop/resume
Up to 24 real-time/date commands
Controller diagnostics
RAM, ROM, pump, display and distributor

On request

All options (2)

Variants & pricing

  • Version
    Standard base
    68-6710-070On request
  • Version
    Jumbo Base
    68-6710-082On request